节点文献

水杨基荧光酮—聚乙二醇辛基苯基醚分光光度法测定钢中微量钛

Spectrophotometric determination of trace Ti (Ⅳ) in steel with the using of salicyl group fluorone and polyglycol caprylpheny ether

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 康桃英; 铁生年;

【Author】 KANG Tao-ying,TIE Sheng-nian(Chemical Engineering College of Qinghai University ,Xining 810016,China)

【机构】 青海大学化工学院; 青海大学化工学院 青海西宁 810016; 青海西宁 810016;

【摘要】 在聚乙二醇辛基苯基醚存在下,研究了钛与水杨基荧光酮的反应特性。结果发现pH在1 20~2 00范围内,形成灵敏度较高的紫红色配合物,其λmax=535nm,ε=1 32×105L·mol-1·cm-1,钛含量在0~0 36μg/mL的测量范围内服从比尔定律。在盐酸羟胺和草酸钠的联合掩蔽下,用此法测定钢中微量钛,获得了满意的结果。

【Abstract】 Under the existance of polyglycol caprlphany ether,the reactive characteristics of salicyl group fluorone and Ti (Ⅳ) were studied. The experiment shows that salicyl group fluorone and Ti (Ⅳ) forms a highly sensitive reddish complex at pH=1.20~2.00,its maximum absorption is at 535 nm,and its molar absorption coefficient is 1.32×105 L.mol-1.cm-1. It is in with the Beer’s law when the concentration of Ti(Ⅳ) ranges from 0 to 0.36 μg/mL. Under the shelbering of hydroxylaminehy drochloride and sodium oxalate, the result of determination of trace Ti(Ⅳ) in bearing-steel sample was satisfactory by using this method.

  • 【文献出处】 青海大学学报(自然科学版) ,Journal of Qinghai University , 编辑部邮箱 ,2004年04期
  • 【分类号】TG115.335
  • 【被引频次】1
  • 【下载频次】55
节点文献中: 

本文链接的文献网络图示:

本文的引文网络