节点文献

冠状动脉造影和介入治疗后应用经皮血管闭合器和常规压迫止血的对比研究

Comparative study on vascular closure by systematic use of a angio-seal after coronary angiography and percutaneous coronary intervention and by manual compression

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 魏宁贾绍斌沙勇仇玉民张金利白向荣汤荣

【Author】 WEI Ning,JIA Shao-bin,SHA Yong,et al.(The Affiliated Hosp. of Ningxia Med. Coll.,Yingchuan 750004,China)

【机构】 宁夏医学院附属医院宁夏医学院附属医院 宁夏银川750004宁夏银川750004宁夏银川750004

【摘要】 目的 观察和评估在冠状动脉造影和介入治疗后即刻在股动脉穿刺处使用Angio -seal血管闭合器的安全性和可靠性。方法  2 32例心血管患者在行心导管术后分为Angio -seal止血组 (115例 ,其中冠状动脉造影5 2例 ,冠状动脉介入术 6 3例 )和人工压迫止血组 (117例 ,其中冠状动脉造影 5 4例 ,冠状动脉介入术 6 3例 ) ,应用两种方法止血 ,观察两组止血时间、下肢制动时间和血管并发症。结果 应用Angio -seal止血器成功率达 97.3% ,与人工压迫止血相比 ,止血时间及下肢制动时间明显缩短 ,心血管并发症发生率低。结论 Angio -seal血管闭合器安全可靠 ,止血快 ,患者下床活动早 ,血管并发症发生率低 ,值得临床推广应用。

【Abstract】 Objective To evaluate the safety and reliability of the closure device for systematic sealing of femoral access site immediately after coronary angiography and percutaneous coronary intervention.Methods Two hundred and thirty two patients who underwent cardiac catheterization procedures were divided into Angio-seal group (115 cases ,52 cases underwent coronary angiography ,63 cases underwent coronary interventional procedures) and manual compression group (117 cases , 54 cases underwent coronary angiography ,63 cases underwent coronary interventional procedures). The time to hemostasis , time to cessation and vascular complication were compared between the two groups.Results The successful hemostasis rate by Angio-seal device was 97.3% . A significant reduction in time to reliable hemostasis , time to cessation and vascular complications were associated with use of the Angio-seal device.Conclusion The Angio-seal device can achieve hemostasis and ambulation faster than manual compression . The use of the Angio-seal device is safe and effective .

  • 【文献出处】 宁夏医学杂志 ,Ningxia Medical Journal , 编辑部邮箱 ,2004年11期
  • 【分类号】R543.3
  • 【被引频次】1
  • 【下载频次】62