优化装置操作 避免离子膜损伤

Optimizing devices operating to avoid ion-exchange membrane hurting

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 许亚洲操斌安志明艾力

【Author】 XU Ya-zhou,CAO Bin,AN Zhi-ming,Aili(Xinjiang Shihezi Zhongfa Chemical Industry Co.,Ltd.,Shihezi 832000,China)

【机构】 新疆石河子中发化工有限责任公司新疆石河子中发化工有限责任公司 新疆石河子832000新疆石河子832000新疆石河子832000

【摘要】 针对新疆石河子中发化工有限责任公司国产化离子膜强制循环电解槽的运行特点,分析了一次盐水、二次盐水质量及开停车对电解槽和离子膜寿命的影响。指出:只有电槽压差稳定,才能保证电解槽平稳运行,避免离子膜受损,延长离子膜使用寿命。

【Abstract】 In view of the running characters of domestic ion-exchange membrane electrolyzer with forced circulation,the influence of the quality of primary and secondary brine,and the running status of start-up or shut-down on the service life of electrolyzer and ion-exchange membrane is analyzed.It is pointed out that:only when the cell voltage of electrolyzer is stabilized,the running of electrolyzer can insure to be smooth and stable so as to avoid ion-exchange membrane hurting and elongate the service life of ion-exchange membrane.

【关键词】 离子膜电解压差平稳运行
【Key words】 ion-exchange membraneelectrolysiscell voltagestable running
  • 【文献出处】 氯碱工业 ,Chlor-alkali Industry , 编辑部邮箱 ,2004年01期
  • 【分类号】TQ114.262
  • 【被引频次】1
  • 【下载频次】49