节点文献

2,4-二羟基苯乙酮缩三羟基甲基氨基甲烷的合成及其在稀土矿样中铽的痕量荧光分析中的应用(英文)

Synthesis of new Schiff base 2,4-dihydroxyl-aceto-phenonetriaminotriethylamine and its application in fluorescence determination of trace amounts of terbium(Ⅲ) in a high purity yttrium oxide

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨天林覃文武刘伟生

【Author】 YANG Tian-lin~(1,2), QIN Wen-wu~1, LIU Wei-sheng~(1,①) (1. College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China; 2. College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan, 750021, China)

【机构】 兰州大学化学化工学院兰州大学化学化工学院 甘肃兰州 730000 宁夏大学化学化工学院宁夏银川 750021甘肃兰州 730000甘肃兰州 730000

【摘要】 合成了一种新的席夫碱配体2,4-二羟基苯乙酮缩三羟基甲基氨基甲烷。该配体与铽(Ⅲ)的配合物的荧光强度在磷酸钠或六次甲基四胺的存在下可增强18或26倍。有机溶剂CH3CN,DMF,丙酮,THF,DMSO,CH3OH,C2H5OH的添加可使其荧光强度进一步增加3~19倍。其中,用CH3CN作溶剂时荧光增加倍数最大,Tb-HL-HMTM体系荧光最强。pH=6.0时,激发和发射波长分别是355和545nm。在理想情况下,荧光强度与Tb3+离子浓度成正比。对于HL-Na3PO4-CH3CN体系,线性范围2.3×10-10~5.8×10-5 mol/L,检测限2.0×10-10 mol/L,对于HL-HMTM-CH3CN体系,线性范围9.8x10-11~7.2×10-5 mol/L,检测限9.0×10-11 mol/L。基于此对Tb3+进行定量测定,该分析方法简单、快速、灵敏、干扰小。同时对荧光增强的机理进行了分析和讨论。

【Abstract】 A new Schiff base ligand, 2, 4-dihydroxyl-acetophenonetriaminotriethylamine(HL), was synthesized and its fluorescence intensity with terbium(Ⅲ) increased by about 18 fold in the presenc of sodium phosphate(Na3PO4) or increased by about 26 fold in the presenc of hexamethylene tetramine(HM-TM). And when organic solvents(CH3CN, DMF, acetone, THF, DMSO, (H3OH, and C2H5OH) were added into the above system, the fluorescence intensities were further enhanced by about 3~19 folds, which was observed to be highest for the Tb-HL-HMTM-CH3CN system(to be about 500 fold). The spectrofluorimetric determination of trace amount of Tb3+ based on the phenomenon was carried out. The excitation and emission wavelengths are 355 and 545 nm, respectively. Under optimal conditions, the fluorescence intensities vary linearly with the concentration of Tb3+ in the range 2.3×10-10~5.8×10-5 mol/L with a detection limit of 2.0×10-1mol/L(for HL-Na3PO4-CH3CN system) or 9.8×10-11~7.2×10-5 mol/L with a detection limit of 9.0×10-11mol/L(for HL-HMTM-CH3CN system). The interferences of some rare earth metals and other inorganic ions were described. The method proves to be a selective, sensitive, rapid and simple analytical procedure for the determination of terbium(Ⅲ) in high-purity yttrium oxide and synthetic samples. The mechanism for the fluorescence enhancement was also studied.

【基金】 Supported by National Natural Science Foundation of China(20371022 and 20071015);Key Project of Chinese Ministry of Education(01170)
  • 【文献出处】 兰州大学学报 ,Journal of Lanzhou University , 编辑部邮箱 ,2004年05期
  • 【分类号】O625;O657.3
  • 【被引频次】2
  • 【下载频次】170
节点文献中: 

本文链接的文献网络图示:

本文的引文网络