节点文献

用新底物DCAP-P检测酸性磷酸酶方法的建立

Novel phosphoric acid derivatives as substrate of acid phosphatase : Synthesis and methodology for determination

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 丁晓琴胡宗华李英谢克勤李忠信

【Author】 DING Xiao-qin*,HU Zong-hua,LI Ying,et al.( *Tianjin Institute of Medical and Pharmaceutical Science,Tianjin 300070,China)

【机构】 天津医药科学研究所制剂中心天津医科大学第二医院检验科天津医科大学第二医院检验科 天津300070天津300070天津300070

【摘要】 目的 合成酸性磷酸酶 (ACP)的底物 2 ,6 二氯 4 乙酰基苯基磷酸 (DCAP P) ,并建立以DCAP P为底物的一种新的ACP测定方法。方法 在BTS 310型半自动分析仪和TBA 4 0FR型全自动生化分析仪上研究连续监测法 ,建立试验参数。结果 本法测定DCAP吸收峰为 32 6nm ;ACP的Km=0 139mmol/L ;340nm时DCAP的摩尔消光系数为 14 4 4 0L·mol 1·cm 1,缓冲液浓度 0 1mol/L ,最适pH5 .4 ,底物浓度 2 0mmol/L ,延滞期 6 0s,线性反应期 15min ;线性范围为 0~ 1188U/L ;血红蛋白 <115 6 2mg/L及胆红素对测定结果无影响 ;本法总ACP与PAP(前列腺酸性磷酸酶 )的参考值范围分别为 12 5 8~ 19 4 2U/L和 2 5 2~9 0 4U/L。结论 此方法重复性好 ,线性反应期长 ,线性范围广 ,干扰因素少 ,适用于自动化分析仪。

【Abstract】 Objective 2,6-dichloro-4-acetylphenylphosphoric acid (DCAP-P) was synthesized as the substrate of acid phosphatase (ACP) for determination of activity and a new method was established.Methods By using semiautomatic and automatic analyzer, a continuous-monitoring procedure was investigated and the experimental parameters were set up.Results Based on the results of ACP in 30 health adults by the determination,the wavelength of DCAP’s absorption was 326nm,and the Km of ACP was 0.139mmol/L,the molecular extinction coefficient of DCAP at 340nm wavelength was 14 440L/(mol×cm).The conditions of reaction were as follows:the concentration of citrate buffer was 0.1 mol/L, the optimum pH of enzyme was 5.4,the concentration of DCAP-P was 2.0mmol/L,the delay time was 60s,the time of linear reaction was 15 minutes and the linear range was 0-1188u/L.The concentration of total ACP and PAP (prostatic acid phosphatase) in serum were 12.58 u/L-19.42 u/L and 2.52 u/L-9.04 u/L respectively.Conclusion The method is convenient,reproducible,time-saving for practice and reliable to be unaffected by bilirubin in serum.It is especially suited to the automatic analyzers.

【基金】 天津市卫生局资助项目 (96KF10 )
  • 【文献出处】 临床检验杂志 ,Journal of Clinical Laboratory Science , 编辑部邮箱 ,2004年06期
  • 【分类号】R446.1
  • 【被引频次】6
  • 【下载频次】92