【摘要】 本文分析和介绍了北京12所医院及医疗单位的空气品质和ASHRAE空调设计标准,结果发现这些医院的空气品质多数不合格,说明一般综合医院空调系统存在许多问题。因此,我们应当制定严格的一般综合医院空调设计标准,尤其是门诊部的空调设计,从而从根本上控制医院感染。
【Abstract】 To prevent hospital infection air quality was analyzed in different sites of twelve hospitals and institutions in Beijing. And the ASHRAE design guideline for the air-conditioning sytems was introduced. Air quality in these hospitals shows that there are many problems in air conditioning systems in hospitals. We should establish strict guideline for air-conditioning systems in hospitals, especitally in outpatient department to radically control hospital infection.