北京地区湿式脱硫除尘系统管路结垢现象分析

Analysis on Scale Phenomenon in the Pipe Line of Wet Dust Removal and Desulfurization System in Beijing Region

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 彭凤仙张俊丰童志权

【Author】 PENG Feng-xian,ZHANG Jun-feng, TONG Zhi-quan (1.Changsha Environmental Protection College, Changsha 410004, China; 2. Department of Environmental Engineering, Xiangtan University, Xiangtan 411105, China)

【机构】 长沙环保职业技术学校湘潭大学环境工程系湘潭大学环境工程系 长沙410004湖南湘潭411105湖南湘潭411105

【摘要】 分析了北京地区供热企业湿式脱硫除尘系统普遍存在的循环水管路结垢问题 ,指出体系中Ca2 + 和SO2 -4的积累是造成结垢的根本原因 ,采用合适的烟气脱硫方法和工艺是解决脱硫设备结垢问题的根本所在 ;添加少量合适絮凝剂是减少循环水系统管路结垢的重要措施。

【Abstract】 The problem of scale in the pipe line of circulating water in wet dust removal and desulfurization system in Beijing region was analyzed and the accumulation of Ca2+and SO 2- 4 was found to be the main cause for scale formation. Moreover, the appropriate desulfurizating method was proposed as the dominating factor to resolve the scaling problem and the addition of some effective coagulant proved to be very useful.

【基金】 国家“九五”重点科技攻关项目 ( 96 910 0 1 0 2 8 0 5 )。
  • 【文献出处】 安全与环境工程 ,Safety and Environmental Engineering , 编辑部邮箱 ,2004年03期
  • 【分类号】X701.3
  • 【被引频次】1
  • 【下载频次】92