节点文献
均匀取样电磁量能器能量纵向泄漏的修正
Longitudinal Leakage Correction of Uniformly Sampling Electromagnetic Calorimeter
【摘要】 研究对铅 -闪烁光纤夹层电磁量能器能量纵向泄漏的纠正 .对AMS0 2电磁量能器 2 0 0 2年束流测试的数据进行了分析 ,用Γ函数拟合的方法和末层沉积能量法对量能器的能量纵向泄漏进行了修正 .经过修正后的能量线性变好 ,能量分辨率显著提高 .末层沉积能量法对于能量分辨率的提高效果更为明显 .
【Abstract】 Correction of longitudinal energy leakage for a lead scintillating fiber sandwiched electromagnetic calorimeter was studied. Electron data from AMS beam test in 2002 was analyzed. Γ-Function-Fit and Last-Layer-Energy-Deposit methods were used to correct longitudinal energy leakage. The linearity and resolution of energy were clearly improved after the correction. And the Last-Layer-Energy-Deposit method is more effective on energy resolution improving.
【关键词】 电磁量能器;
能量分辨率;
Γ函数拟合;
能量泄漏修正;
【Key words】 calorimeter; energy resolution; Γ function fit; energy leakage correction;
【Key words】 calorimeter; energy resolution; Γ function fit; energy leakage correction;
【基金】 国家自然科学基金 (10 0 9963 1)资助~~
- 【文献出处】 高能物理与核物理 ,High Energy Physics and Nuclear Physics , 编辑部邮箱 ,2004年11期
- 【分类号】TL817
- 【被引频次】1
- 【下载频次】54