节点文献

发电机内冷水微碱性循环处理技术的应用

Application of Recycling Technology with Weak Alkaline Water for Internal Cooling System of generator

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 邱胜瑞付元虎何玖琪张党沐徐锐

【Author】 Qiu Sheng-rui,Fu Yuan-hu,He Jiu-qi

【机构】 江西丰城发电有限责任公司江西省电力试验研究院 江西丰城331100江西丰城331100江西南昌330006

【摘要】 介绍江西丰城电厂3号机组应用发电机内冷水微碱性循环处理技术的经验和技术原理。江西丰城电厂为了减缓发电机铜线棒的腐蚀,改变传统的采用添加铜缓蚀剂、频繁换水作为发电机内冷却水的调节方式,采用发电机内冷水微碱性循环处理技术。内冷却水通过微碱性处理后含有微量的氢氧化钠,有效地减缓了发电机线棒的腐蚀。

【Abstract】 In order to alleviate the erosion of large generator’s copper bar,the means of adding copper inhibitor,changing water frequently are introduced by Jiangxi Fengcheng Electric Plant.However,but the quality of water is poor,and it cannot meet the standard of DL/T801-2002“Requirements of water quality and internal cooling water system for large generator".In this paper,the application experience the principle of recycling technology with weak alkaline water for internal cooling system in the No.3 unit of FCEP is primary introduced.The internal cooling water after treatment contains very little NaOH,and its quality is much better than the standard in DL/T801-2002,Under these water quality conditions,copper is in the state of self-passivity.Thus,the copper bar is protected well.

  • 【文献出处】 江西电力 ,Jiangxi Electric Power , 编辑部邮箱 ,2004年03期
  • 【分类号】TM31
  • 【被引频次】2
  • 【下载频次】63
节点文献中: 

本文链接的文献网络图示:

本文的引文网络