节点文献

s-BLM生物传感器CV特性的研究

Studies on the CV Characteri-stics of S-BLM Biosensor

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 陈国明韦云隆刘盛平

【Author】 CHEN Guo-ming~(1,2),WEI Yun-long~2,LIU Sheng-ping~2 (1.Department of Mechatronics,Shantou University,Shoutou 515063;China;2.College of Bioengineering,Chongqing Institute of Technology,Chongqing 400050,China)P75

【机构】 重庆工学院生物工程学院重庆工学院生物工程学院 重庆 400050汕头大学机电系汕头 515063重庆 400050重庆 400050

【摘要】 改进金属探针的制作方法,并对未覆膜的探针进行机械处理与化学活化处理。检测了未修饰s BLM成膜过程的CV特性变化、未修饰s BLM和I2修饰s BLM在不同浓度KI溶液中的CV响应。实验发现I2修饰的s BLM对I 的运载能力不足以使得CV曲线出现明显的氧化还原峰,但可以在氧化还原电位以下进行CV扫描,通过电流大小来判断I 浓度大小。

【Abstract】 The method of making a probe was improved and the metal of the probe was treated with an mechanical and chymic methods.The Current-Voltage characteristics of unmodified s-BLM has been tested during its formation,and that of unmodified s-BLM and s-BLM modified with iodine in different KI solutions were studied.It shows that there is no obvious redox current of s-BLM modified with iodine.But the concentration of I can be distinguished by the CV screening under the redox voltage.

【基金】 国家自然科学基金资助项目(50175067、50375165);广东省自然科学基金资助项目(2000073);广东省教育厅自然科学研究基金资助项目(200063)。