【摘要】 采用光学显微镜、扫描电镜等测试手段 ,对断裂的 5B0 5 (LF1 0 )防锈铝预绞丝进行了分析。结果表明 ,由于退火处理不规范及金属夹杂物的存在 ,引起零件的强度增高、韧性降低 ,在外力的作用下 ,导致预绞丝断裂失效
【Abstract】 Fracture analysis of 5B05 (LF10) antirust aluminium preformed armor rods were studied by metallography and SEM.The results show that the fracture of the antirust aluminium preformed armor rods result from theirs improper annealling as well as the metallic inclusions,causing strength increasing and toughness decreasing and broken under external force action.
【关键词】 失效分析;
防锈铝预绞丝;
断裂;
扫描电镜;
【Key words】 failure analysis; antirust aluminium of preformed armor rods; fracture; SEM;
【Key words】 failure analysis; antirust aluminium of preformed armor rods; fracture; SEM;