节点文献

国产胆道金属支架的临床应用

The clinical application of domestic biliary metallic stents

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 罗祖炎陈方宏袁建华俞文强刘子江

【Author】 LUO Zu-yan, CHEN Fang-hong, YUAN Jian-hua, et al. Department of Radiology, Zhejiang Provincial People’s Hospital, Hangzhou 310014, China

【机构】 杭州浙江省人民医院放射科杭州浙江省人民医院放射科 310014310014

【摘要】 目的 探讨国产胆道金属支架应用的安全性及临床疗效。方法 对 72例 (70例恶性 ,2例良性 )阻塞性黄疸患者施行经皮经肝穿刺植入国产胆道金属支架 75枚。结果  6 6例胆道金属支架植入成功 ,技术成功率 92 .7% (6 6 72 )。支架植入术后 1个月内黄疸缓解率 97.0 % (6 4 6 6 ) ,30d内死亡 2例 ,早期并发症发生率 7.6 % (5 6 6 )。 4 4例随访 2~ 2 4个月 ,随访率 6 6 .7%。 4 2例恶性患者 ,随访 5~ 16个月 (平均 11.6个月 ) ,9例存活 ,33例死亡 ;生存时间 2~ 2 3个月 ,中位生存期 5 .3个月。随访 3、6、12个月的支架通畅率分别为 92 .8%、89.9%、79.4 %。支架再阻塞率 14 .3% (6 4 2 ) ,中位阻塞期 3个月。 2例良性梗阻患者 ,1例支架术后 2 4个月仍通畅 ,1例术后 3个月因其他原因死亡。结论 国产胆道金属支架使用方便 ,临床应用安全可靠 ,具有临床推广价值。

【Abstract】 Objective To determine the clinical efficacy and safety of domestic biliary metallic stents in the management of biliary obstruction. Methods 75 domestic biliary metallic stents were implanted in 66 of 72 patients with obstructive jaundice due to malignant (n=70) and benign stenoses (n=2). Results The technical successful rate was 92.7% (64/66). Palliation with rid of jaundice was achieved in 96.9% (64/66) within 1 month. The 30-day mortality rate was 3% (2/66). Early complications occurred in 7.6% (5/66). 44 patients were followed from 2 to 24 months after treatment. 33 (33/42) of 42 patients with malignancy died after a median survival of 5.3 months (range 2-23 months). The remaining 9 patients (9/42) remained alive with a mean follow-up of 11.6 months. The stent patency rates were 92.8%,89.9% and 79.4% at 3,6,12 months respectively. 6 patients (6/42) presented stent occlusion within a median period of 3 months. One of two patients with benign stenoses sustained a patency duration time of 24 months. One patient died 3 months after treatment. Conclusions The domestic biliary metallic stent implantation is efficacy and safety in the management of biliary obstruction.

【关键词】 胆管阻塞金属支架黄疸引流术
【Key words】 Biliary obstructionMetallic stentJaundiceDrainage
  • 【文献出处】 介入放射学杂志 ,Journal of Interventional Radiology , 编辑部邮箱 ,2004年05期
  • 【分类号】R575
  • 【被引频次】13
  • 【下载频次】82
节点文献中: 

本文链接的文献网络图示:

本文的引文网络