节点文献
落管中双波长测温的工作波长选择
Selection of Working Wavelengths of Dual-Wavelength Temperature Measurementin Drop Tubes
【摘要】 根据测量所要求的动态范围、线性度、灵敏度,通过数值计算得出落管中双波长温度测量中的工作波长及带宽的最佳范围,结合实际情况最终确定工作波长为 1.4 μm 和 1.55 μm,其带宽均为 0.03μm。
【Abstract】 According to the dynamic range of measurement, linearity and sensitivity, the optimal range of working wavelengths and the corresponding bandwidths were determined by numerical calculation. Combined with practical factors, two working wavelengths of 1.4 μm and 1.55 μm were selected, whose bandwidths both being 0.03 μm.
【关键词】 双波长;
温度测量;
波长选择;
落管;
【Key words】 temperature measurement; dual-wavelength; wavelength selection; drop tube;
【Key words】 temperature measurement; dual-wavelength; wavelength selection; drop tube;
【基金】 国家自然基金资助项目(批准号:50271076)
- 【文献出处】 红外技术 ,Infrared Technology , 编辑部邮箱 ,2004年06期
- 【分类号】TH811
- 【被引频次】3
- 【下载频次】62