【作者】 苏金钰田学达

【Author】 SU Jin-yu1, TIAN Xue-da2 (1.Department of Environmental Sciences,colleage of Hunan environment-Biological,Hengyang 421005 Hunan;2.Department of Environmental Engineering, Xiangtan University,Xiangtan 411105 Hunan)

【机构】 湖南环境生物职业技术学院环境科学系湘潭大学环境工程系 湖南衡阳421005湖南湘潭411105

【摘要】 本文采用活性炭负载TiO2作催化剂对臭氧氧化去除含酚废水进行了研究.研究了不同的酚初始浓度、pH值及臭氧浓度对苯酚去除率的影响,获得了反应动力学常数.实验结果表明苯酚初始浓度越小,去除率越高.在本实验条件下,向150mL苯酚溶液中通入浓度为3.48mg/L、流量为0.05m3/h的臭氧化空气反应30min去除率即可达到99%以上.

【Abstract】 Phenol in water was removed by ozonation with the catalysis of TiO2-mounted activated carbon. In this experiment, the effects of factors such as the initial concentration of the phenolic solution, pH value and the concentration of the ozone ,on the removal efficiency of phenol were investigated. The reaction kinetics and its constant was investigated. On the studied conditions, pumped the mixed ozone at the concentration of 3.48 mg/L and 0.05 m3/h, after 30 mins, 99 % of the phenol was removed.

【关键词】 苯酚TiO2臭氧氧化催化动力学
【Key words】 phenoltitanium dioxideozonationcatalysiskinetics