【摘要】 采用由程序控制的自动采样器、自动稀释器和流动注射 微生物传感器组成的BOD在线自动监测仪 ,对污水BOD进行了在线自动监测。用该仪器监测配制标样和质控标样的结果具有良好的准确度和精密度。该仪器安装于污水处理厂出水口 ,连续运行 1 0d状态良好 ,且测定结果与标准稀释法测得的BOD5有良好的相关性

【Abstract】 The sewage’s BOD 5 was determined by an on line and auto monitoring instrument, which consisted of automatic sampler system, automatic diluting device, flow injection system and BOD 5 microbial sensor. The standard sample and quality control sample have been determined by this instrument, the results were of the good accuracy and the good precision. This instrument was erected at outlet of a sewage treatment plant, whose results were agreed well with those by standard method (BOD 5).