节点文献

用热水示踪技术测量蒸馏塔板上液体返混的微机温度测量装置

Measurement of Backmixing on Distillation Trays Using Computerized Multipass Thermometer with Hot Water as Tracer

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 姬登祥俞晓梅李育敏顾卫国张建正

【Author】 Ji Dengxiang 1,Yu Xiaomei 1,Li Yumin 1,Gu Weiguo 1,Zhang Jianzheng 2 (1 College of Chemical Engineering & Material, Zhejiang University of Technology,Hangzhou 310014; 2 Department of Automation,East China University of Science & Technology,Shanghai 200237)

【机构】 浙江工业大学化工与材料学院华东理工大学自动化系 杭州310014杭州310014上海200237

【摘要】 对测量塔板上液体返混的温度测量仪进行了调试研究 ,仪器的测量精度为 1.5级 ,时间常数为4 .0~ 4 .8s,相对滞后时间为 0 .0 5~ 0 .3s。仪器有良好的重复性和分辨能力 ,采用激励 响应技术用热水做示踪 ,通过对涡流扩散系数测试值和计算值的比较 ,仪器的测量结果准确可靠。

【Abstract】 The liquid backmixing on the distillation trays effects the plate efficiency. In this paper,the computerized multipass thermometer used to measure liquid backmixing on the trays was studied. This apparatus adopts the stimulus-response technology using hot water tracer,with its measuring precision of 1.5 rate, time constant of 4.0~4.8 s and relative lagging time of 0.05~0.3 s.So it has good recurrence and resolving power. By comparing the liquid eddy diffusion efficient from the AIChE correlation with that from the experiment,the measuring results of computerized multipass thermometer are satisfactory.

  • 【文献出处】 化工进展 ,Chemical Industry and Engineering Progress , 编辑部邮箱 ,2004年05期
  • 【分类号】TQ05
  • 【被引频次】2
  • 【下载频次】59
节点文献中: 

本文链接的文献网络图示: