节点文献

蒸汽—热泵联合干燥木材能耗的实验测试与分析

Experiment and analysis on energy consume of steam-heat pump combined drying wood

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张璧光; 宁炜;

【Author】 ZHANG Bi-guang1, NING Wei2 (1. College of Material Science and Technology, Beijing Forestry University, Beijing 100083, China; 2. Heat Pump Technology Department, Tsinghua Tongfang Artificial Environment Co. LTD, Beijing 100083, China)

【机构】 北京林业大学材料科学与技术学院; 清华同方人工环境有限责任公司热泵技术研发部 北京100083; 北京100083;

【摘要】 从实验方面对单独的常规蒸汽干燥、热泵(除湿)干燥以及二者联合干燥进行了实验测试及分析,结果显示热泵(除湿)干燥最节能,但干燥周期最长,联合干燥虽然比除湿干燥能耗高 18%,但比蒸汽干燥节能 27.3%,干燥周期比除湿干燥缩短了近一半,大大提高了生产率。

【Abstract】 The conventionalsteam drying, the heatpump (dehumidification)drying andsteam-heatpump combined drying are tested and analyzed. It results that heat pump dehumidification) drying consumes the least energy, ( but its drying time is the longest, and that combined drying consumes more than the dehumidification drying by 18 percent, but less than the steam drying by 27.3 percent. Comparing with the dehumidification drying, its time decreases by half.

  • 【文献出处】 华北电力大学学报 ,Journal of North China Electric Power University , 编辑部邮箱 ,2004年06期
  • 【分类号】TS653
  • 【被引频次】18
  • 【下载频次】231
节点文献中: 

本文链接的文献网络图示:

本文的引文网络