节点文献
氟离子测定的离子选择电极法中标准加入法的改进
Improvement of Standard Addition Method of Ion-selective Electrode on Fluorine Ion Determination
【摘要】 本文对离子选择电极法测定氟离子的一次标准加入法改进为微量标准加入法进行了研究 ,结合采用标准斜率校正法 ,解决了原方法计算复杂、受温度影响大等缺点
【Abstract】 Micro-standard addition method was presented by improving standard addition method of ion-selective electrode on fluorine ion determinatiom.The disadvantages of original method including the complicated calculation and the serious temperature influences were solved by the modified method.
- 【文献出处】 广州化工 ,Guang Zhou Chemical Industry and Technology , 编辑部邮箱 ,2004年01期
- 【分类号】O657.1
- 【被引频次】12
- 【下载频次】501