节点文献

评价国产13C-尿素呼气试验药盒诊断幽门螺杆菌感染的效果

Evaluation the effects of a homemade 13C-labelled urea capsules in detecting Helicobacter pylori infection

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 谢鹏雁刘新光陈绍亮李培勇吴靖川严建朱瑞森

【Author】 XIE Peng-yan1, LIU Xin-guang1,CHEN Shao-liang2, LI Pei-yong3,WU Jing-chuan4, YAN Jian5,ZHU Rui-sen6(1.Department of Gastroenterologe,First Hospital of Peking University,Beijing 100034, China;2.ZhongshanHospital of Fudan University,Shanghai 200032, China;3.RuijinHospital of Shanghai Second MedicalUniversity, Shanghai 200025, China;4.Xinhua Hospital of ShanghaiSecond Medical University, Shanghai200029, China;5.Xuhui DistrictCentral Hospital, Shanghai 200003,China;6.Sixth People Hospital ofShanghai, Shanghai 200233, China)

【机构】 北京大学第一医院消化内科复旦大学中山医院上海第二医科大学瑞金医院上海第二医科大学新华医院上海市徐汇区中心医院上海市第六人民医院 北京100034北京100034上海200032上海200025上海200092上海200003上海200233

【摘要】 目的 评价国产13C-尿素呼气试验药盒诊断幽门螺杆菌(Hp)感染的效果。方法 用多中心随机开放平行对照试验,门诊或病房病人共139例,试验组69例,对照组70例,经快速尿素酶试验和WS银染色检查确定幽门螺杆菌感染,分别用国产或进口13C-UBT药盒,用质谱仪行13C-尿素呼气试验检测Hp感染,比较不同药盒诊断Hp感染的敏感性、特异性,观察其药物不良反应。结果 试验组诊断Hp的敏感性为100%,特异性为88.2%,准确度为94.2%;对照组诊断Hp的敏感性为97.1%,特异性为94.3%,准确度为95.7%。2组比较无显著性差异(P>0.05)。药物不良反应轻微。结论 用国产13C-尿素呼气试验药盒诊断Hp感染与进口试剂无明显差异,对简单、非侵入性的Hp感染诊断试验安全、可靠。

【Abstract】 Objective To evaluate the sensitivity, specificity and safety of a homemade13C-labelled urea capsules in detecting Helicobacter pylori infection. MethodsThe study is a randomized, open, parallel-controlled, multicentre clinical trial carriedout in 6 medical units of Beijing and Shanghai. Helicobacter pylori infection wasproven by rapid urease test and Warthin-starry staining. Patients were randomlydivided into trial group taking 75mg homemade 13C-UBT kit or control group taking75mg commercial available 13C-UBT kit. Blood routine test, liver and renal functionwere examined before and 1 week after the UBT test. Results Total 139 subjects wereenrolled into the study, 69 in trial group and 70 in control group. There were nosignificant differences in age and sex between the two groups. There were nosignificant difference in the sensitivity, specificity and precision in detectingHelicobacter pylori infections between the two groups, which were 100%, 88.2% and94.2% in trial group and 97.1%, 94.3% and 95.7% in control group. Decreased WBCin 1 patient and increased ALT level in 2 patients of trial group were mild, no otheradverse effects were found. Conclusion The homemade 13C-UBT kit was aseffective and safe as the import kit, also to be a simple, non-invasive and reliable testfor the diagnosis of Helicobacter pylori infection.

  • 【文献出处】 中国临床药理学杂志 ,The Chinese Journal of Clinical Pharmacology , 编辑部邮箱 ,2004年06期
  • 【分类号】R573
  • 【下载频次】119
节点文献中: 

本文链接的文献网络图示:

本文的引文网络