节点文献
多回路输电线路上使用合成绝缘子有关问题的探讨
Discussion about Using Composite Insulator on Transmission Line of Multiple Circuits
【摘要】 文章阐述了合成绝缘子耐雷性能的两面性;分析了在多雷区多回路输电线路上,杆塔比较高时,线路绝缘往往受大气过电压控制,由于合成绝缘子雷电冲击耐压水平较低,因此其使用受到限制,建议对有关规定提出修订。
【Abstract】 In this paper the author described both aspects of withstand - lightning characteristic of composite insulator, and analyzed that as the insulation of multiple circuits is often controlled by atmosphere over- voltage in heavy- lightning area when the towers are higher, so that its application would be limited, and gave an advice to revise relative rule.
【关键词】 线路绝缘;
合成绝缘子;
雷击跳闸率;
雷电冲击电压;
【Key words】 Line insulation Composite insulator Lightning trip-out rate Lightning-impulse voltage;
【Key words】 Line insulation Composite insulator Lightning trip-out rate Lightning-impulse voltage;
- 【文献出处】 广东输电与变电技术 ,Guangdong Power Transmission Technolo , 编辑部邮箱 ,2004年01期
- 【分类号】TM75
- 【下载频次】50