CO2 Laser Collective Thomson Scattering Diagnostics on the HT-7 Tokamak
【摘要】 <正>A CW CO2 laser collective Thomson scattering diagnostics was developed to measure plasma density fluctuations on the HT-7 tokamak. The design and construction of CO2 laser scattering apparatus is described. The laser source is a continuous-wave CO2 laser with a cavity length of 1.9 m and a power output of about 10 W at 10.6 μm. The k-resolution of the system is △k ≈ 3.2 cm-1. The preliminary data from the diagnostic is presented.
【Abstract】 A CW CO2 laser collective Thomson scattering diagnostics was developed to measure plasma density fluctuations on the HT-7 tokamak. The design and construction of CO2 laser scattering apparatus is described. The laser source is a continuous-wave CO2 laser with a cavity length of 1.9 m and a power output of about 10 W at 10.6 μm. The k-resolution of the system is △k ≈ 3.2 cm-1. The preliminary data from the diagnostic is presented.
【Key words】 collective scattering; density fluctuation; CO2 laser;
- 【文献出处】 Plasma Science & Technology ,等离子体科学和技术(英文版) , 编辑部邮箱 ,2004年06期
- 【分类号】TN248