宽支撑防风型芒刺电晕线的试验研究

Test and Study on Wide Support Electrode with Windproof

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 胡满银高维英刘松涛刘同欣高香林

【Author】 Hu Manyin, Gao Weiying, Liu Songtao, Liu Tongxin, Gao Xianglin (North China Electric Power University, Baoding City Hebei Province, 071003)

【机构】 华北电力大学华北电力大学 河北省保定市071003河北省保定市071003

【摘要】 反电晕和二次扬尘是提高电除尘器的除尘效率所面临的两大难题。采用一种宽支撑防风型芒刺电晕线 ,它加大了阴极收尘面积 ,防风措施减小了阴极二次扬尘。在实验室中对这种电晕线进行了放电特性试验研究 ,证明它可以有效地避免或减少反电晕的发生 ,改善板电流密度分布的均匀性 ,提高电除尘器的除尘效率 ,是解决高比电阻粉尘问题的有效措施

【Abstract】 The discorona and re-entrain dust are two key issues to improve the efficiency of the electric precipitator. Application of a wide-support windproof electrode can increases the dust collection area of the electrode and windproof reduces the re-entrain dust on the electrode. The test on the discharge characteristic of this electrode in the laboratory has indicated that it can effectively avoid or reduce the occurrence of discorona, improve the distribution uniformity of current intensity and increase the dust removal efficiency of the precipitator. So this is an effective measures to solve the high ratio resistance dust.

  • 【文献出处】 电力建设 ,Electric Power Construction , 编辑部邮箱 ,2004年11期
  • 【分类号】TM733
  • 【下载频次】49