节点文献
检测CO2的脉冲电势调制库仑技术
Investigation of Pulse Potential-modulated Coulometry for CO2 Detection
【摘要】 应用脉冲电势调制技术,通过控制电极电势可将CO2还原为以吸附COads为主的中间物;之后再将电极电势阶跃到该物种能发生电化学氧化的电势,测量它的暂态氧化电流,得到积分电量Q随被测CO2浓度C的变化关系.对给定的还原时间,在CO2浓度为0.015%~20%的范围内,氧化电量Q与CO2浓度C有确定的对应关系.其中,当还原时间较短及CO2浓度较低情况下,两者有近似线性关系.这是一种可在较宽浓度范围内测定CO2的简便有效方法.
【Abstract】 A pulse potential-modulated technique was applied to measure the concentration of CO2 in gas samples. In the first step, an anodic pulse and a consequent cathodic pulse were used to remove the organic pollutant and surface oxide on the surface of the platinized Pt gauze electrode before each experiment. As following, a given potential step was used to reduce the CO2 into adsorbed intermediate on Pt surface, and the adsorbates produced were oxidized by a following anodic potential step. At same time the oxidation current of adsorbates were measured. A certain relation exists between the concentration of CO2 and the oxidation charge within the concentration range of (0.015)% to 20%. The approximate linear concentration-charge relation appears during a shorter reduction period and at a lower concentration of CO2. It’s wide convenient and effective for the detection of CO2 in a relatively wide concentration range.
【Key words】 Sensor; Carbon dioxide; Pulse potential-modulated; Solid polymer electrolyte; Pt (electrode);
- 【文献出处】 电化学 ,Electrochemistry , 编辑部邮箱 ,2004年04期
- 【分类号】O646.5
- 【下载频次】52