节点文献

黄铜腐蚀速度与Cl~-浓度的关系

Relation Between Corrosion Rate of Brass and Concentration of Chloride Ion

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王志武原素芳

【Author】 WANG Zhi-wu, YUAN Su-fang (Department of Material Engineering, Wuhan University, Wuhan 430072, China)

【机构】 武汉大学材料工程系武汉大学材料工程系 湖北武汉430072湖北武汉430072

【摘要】 为了定量确定黄铜腐蚀与Cl-浓度的关系,对HSn70-1A、HAl77-2A两种黄铜进行静态挂片浸泡试验,并根据试验数据拟合了关系曲线。试验结果表明,在含Cl-的水溶液中HSn70-1A较HAl77-2A腐蚀严重;HSn70-1A、HAl77-2A的腐蚀速度随Cl-浓度的变化均呈三次方关系,区别在于HAl77-2A的腐蚀速度随Cl-浓度的变化较为平缓,而HSn70-1A的腐蚀速度随Cl-浓度的变化较为显著,HSn70-1A的腐蚀对Cl-较HAl77-2A更为敏感。

【Abstract】 In order to quantitative determine the relation between brass corrosion and concentration ofCl~-, static coupon test was carried on for two kinds of brasses HSn70-1A and HA177-2A, and experimental data was fitted into curve.The results make clear that there are both cubic relations between corrosion rates of two brasses and C1-concentration, the difference lies in that the corrosion rate change of HSn70-1A brass with C1-concentration is more obvious than HA177-2A, so HSn70-1A brass is more sensitive to corrosion of C1 than HA177-2A brass.

【关键词】 腐蚀黄铜Cl-静态挂片试验
【Key words】 corrosionbrassCl~-static coupon test
  • 【文献出处】 材料保护 ,Materials Protection , 编辑部邮箱 ,2004年10期
  • 【分类号】TG174.4
  • 【被引频次】46
  • 【下载频次】539
节点文献中: 

本文链接的文献网络图示:

本文的引文网络