节点文献

岩石中微量铅分离方法的实验研究

Method study of separating micro lead from rock

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 周燕王铁夫咸嘉泉张延洁

【Author】 ZHOU Yan,WANG Tie-fu,XIAN Jia-quan,ZHANG Yan-jie (Center of Scientific Experiment and Testing,Jilin University, Changchun130026,China)

【机构】 吉林大学测试科学实验中心吉林大学测试科学实验中心 吉林长春130026吉林长春130026吉林长春130026

【摘要】 介绍了一种分离岩石中微量铅及超微量铅的新方法。在此方法中首先采用Dowexl×8阴离子交换树脂,使铅与绝大多数金属离子分离,然后采用阳极电解法使铅进一步纯化。全流程空白为(2~4)×10-11g/mg。这样制备出的样品消除了铅质谱分析的干扰元素,提高了质谱测试精度。质谱分析时,采用NBS981对铅同位素进行分馏校正,进一步提高了分析精度,质谱测试精度均高于1‰。

【Abstract】 The authors reports a new method of separating micro lead and super micro lead from rock, in which Dowex l×8 anion exchanged resin is used. First,the micro lead is separated from most metallic ions. Second, the lead is purified by using the method of the anodic electrolyze. The background of the process is (2~4)×10-11g/mg. In this way,there are no interference elements in the sample of mass spectrum analysis and the precision of mass spectrum analysis is improved. When analysing mass spectrum of the lead the authors can calibrate the fractionation of the lead isotope by NBS981.The higher precision of mass spectrum analysis can be obtained. The precision of mass spectrum analysis is up to 1‰.

【关键词】 微量铅阴离子交换阳极电解
【Key words】 micro leadanion exchangeanodic electrolyze
  • 【文献出处】 吉林大学学报(地球科学版) ,Journal of Jiling University (Earth Science Edition) , 编辑部邮箱 ,2004年02期
  • 【分类号】O657.63
  • 【被引频次】2
  • 【下载频次】80
节点文献中: 

本文链接的文献网络图示:

本文的引文网络