节点文献
转炉氧枪自锁装置的改造
Reform of Oxygen Lance Self-lock Installation in Converter
【摘要】 分析了氧枪坠落事故的根本原因。经周密计算 ,自行设计了氧枪自锁装置。该装置投资少 ,安全性高 ,已成功防止氧枪坠炉事故的发生。
【Abstract】 The basic reasons leading to oxygen lance falling are analyzed. The self-lock installation of oxygen lance is designed on the basis of careful calculation. Owing to low investment and high security, the installation has successfully prevented oxygen lance from falling.
- 【文献出处】 鞍钢技术 ,Angang Technology , 编辑部邮箱 ,2004年06期
- 【分类号】TF341
- 【下载频次】68