节点文献

红外吸收法测定钼铁中碳、硫

Determination of carbon and sulfur in ferromolybdenum by high frequency-infrared absorption method

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 赵宇宋立伟

【Author】 ZHAO Yu,SONG Li-wei (Centre of Chemical and Physical Test,Anshan Iron and Steel Complex,Anshan 114021,China)

【机构】 鞍山钢铁集团公司化检验中心鞍山钢铁集团公司化检验中心 辽宁鞍山114021辽宁鞍山114021

【摘要】 应用高频红外碳硫仪 ,建立了钼铁合金中碳硫测定方法 ,对选择适当的测定条件如助熔剂 ,分析时间等进行了探讨 ,最佳测定条件 :最大工作电流为 40 0mA ;载气流速为 3L/min ;载气 (氧气 )纯度为 99 99% ;陶瓷坩埚需经 110 0℃灼烧 2h后 ,可使空白降至最小 ;C元素最短分析时间为 3 0s,比较水平为 1 0 0 ;S元素最短分析时为 40s ,比较水平为 5 0 0。

【Abstract】 A rapid method for the determination of carbon and sulfur in ferromolybdenum by using high frequency-infrared absorption was presented,the analytical conditions have been discussed,such as flux,analytical time.The conditions of measurement were as follows: work current was 400mA; flow capacity of carrying gas was 3L/min; purity of oxygen was 99.99%;analytical period was 30s for carbon and 40s for sulfur.The results obtained were satisfactory.

  • 【文献出处】 冶金分析 ,Metallurgical Analysis , 编辑部邮箱 ,2003年01期
  • 【分类号】TG115.3
  • 【被引频次】4
  • 【下载频次】86
节点文献中: 

本文链接的文献网络图示:

本文的引文网络