节点文献
严重烧伤病人尿管留置的细菌学检测和护理
Bacteriological detection and nursing of severely burned patients with indwelling catheter
【摘要】 目的:探讨严重烧伤病人留置尿管与尿路感染的关系。方法:分别于留置尿管后第1天、3天、7天、10天、14天、20天采样进行细菌学检测。结果:留置尿管时间与菌尿感染发生率成高度正相关。检出细菌种类依次为:白色念珠菌、阴沟肠杆菌、绿脓杆菌、大肠杆菌、硝酸盐阴性杆菌、金黄色葡萄珠菌。结论:留置尿管持续时间越长,细菌检测率越高,且真菌感染率也呈上升趋势。
【Abstract】 Objective: To find the correlation between urinary tract infection and the indwelling catheter of theseverely burned patients. Method: Bacteriological detection was made on 1, 3, 7, 10, 14 and 20 days post catheterindwelling. Results: There was a close correlation between urinary tract infection and the indwelling catheter. Candidaalbicans, Aerobacter cloacae, Bacillus pyocyaneus, Bacillus Boli, nitate negative bacillus, Staphylococcus aureus weredetected. Conclusion: The longer the time of catheter indwelling the higher the detectable rate of the bacteria and also thehigher the rate of fungal infection.
- 【文献出处】 中国烧伤创疡杂志 ,The Chinese Journal of Burns Wounds & Surface Ulcers , 编辑部邮箱 ,2003年02期
- 【分类号】R473.6
- 【下载频次】25