发电厂厂址防洪措施的优化分析
Optimizing Analysis of Flood Prevention Measures of a Certain Power Plant Area
【摘要】 介绍了某发电厂厂址P =1%洪水位的推求 ,并结合厂址具体情况 ,进行几种防洪措施的技术经济比较。
【Abstract】 This article introduces the calculation of 1% frequency high water level of a certain power plant area. According to the detail of the power plant area, several flood prevention measure are compared in respect of economy and technology.
- 【文献出处】 山东电力技术 ,Shandong Electric Power , 编辑部邮箱 ,2003年01期