自制APTT试剂在Coachrome IV仪器上的应用

The Application of Self-made APTT Reagents on the Apparatus “Coachrome IV”

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张金莲范锡英郭先红

【Author】 Zhang Jinlian ,et al. (Analysis and Test Lab Center of Xinxiang Medical College, Xinxiang, Henan ,China 453003)

【机构】 新乡医学院分析测试中心洛阳医学专科高等学校 河南河南河南453003

【摘要】 目的 探讨自制活化部分凝血活酶试剂的应用效果。方法 用自制活化部分凝血活酶试剂与进口活化部分凝血活酶试剂同时在“CoachromeIV”血凝仪上检测不同水平凝血因子及不同浓度肝素的血浆APTT和 5 6例患者血浆的APTT。结果 两种试剂对不同水平凝血因子及肝素的敏感性基本一致 ,并且相关性良好 (r =0 .975 6 ,P <0 .0 1)。结论 自制活化部分凝血活酶试剂可以代替进口活化部分凝血活酶试剂。

【Abstract】 Objective To investigate the effectiveness of the activated partial thromboplastion time (APTT) reagent self-made and of the imported reagent.Methods APTT of different plasma level of coagulation factors with heparin,and as well as APTT 0f 56 patients plasma were measured by the reagents on the appartus “Coachrome IV”. Results The sensitivity of APTT the two reagents didn`t change with different levels of plasma coagulation factor and heparin, there was rectilinear correlation in APTT ratio (r = 0.9756 P < 0.01). Conclusions The homemade activated partial thromboplastion time (APTT) reagent can replace the imported reagent.

  • 【文献出处】 齐齐哈尔医学院学报 ,Journal of Qiqihar Medical , 编辑部邮箱 ,2003年09期
  • 【分类号】R446.1
  • 【被引频次】1
  • 【下载频次】57