节点文献
电站高温再热器爆管分析
BURST ANALYSIS OF HIGH TEMPERATURE RE-HEATER PIPE OF POWERSTATION
【摘要】 某电站高温再热管在运行了仅 3× 10 4 h后发生了爆裂。为研究其爆裂原因 ,对不同状态下的再热管进行取样 ,进行了化学分析、宏微观检验和力学性能测定。结果表明 ,由于运行中的再热管局部过热 ,造成管壁严重的氧化而减薄 ;同时又引起该区域组织发生变化 ,这样就大大降低了材料的力学性能。由于在这种条件下的长期运行 ,使材料的性能不断恶化 ,最终导致再热管爆裂
【Abstract】 The burst of high temperature re-heater pipe of powerstation occured when it operating over 30000 hours. It causes a lot of enormous losses. This article researchs the cause of cracking by means of macroscopic inspection, mechanical property testing etc. It was found that the cracking is induced by the partial superheat and superpressure. We put forward a proposal for improving the management of this eguipment.
【关键词】 电站高温管;
爆裂;
过热;
过压;
【Key words】 High temperature pipe of power station; Burst; Superheat; Superpressure;
【Key words】 High temperature pipe of power station; Burst; Superheat; Superpressure;
- 【文献出处】 理化检验(物理分册) ,Physical Testing and Chemical Analysis Part A Physical Testing , 编辑部邮箱 ,2003年07期
- 【分类号】TK228
- 【被引频次】5