【摘要】 通过对各星级宾馆中央空调实际制冷量配置的统计分析 ,确认夏季制冷时只要回收中央空调散热量的 5 0 %来制备热水 ,即可满足《建筑给水排水设计规范》(GBJ15 - 88)第四章规定的宾馆饭店生活热水耗热量的要求 ,从而得出发展用空调散热回收制备热水技术可以做到在夏季满负荷制冷期间基本无需再运行专设的锅炉或电加热设备 ,就可保证宾馆饭店生活热水供应的结论。并对各种空调余热回收制备生活热水技术方案进行了探讨和热工分析

【Abstract】 On the basis of an investigation of central air condition capacity for star hotels, it is believed that 50% of the radiating heat of air condition will be sufficient to hot water preparation in summer time for the hotel itself according to the Design Norm of Building Hot Water System GBJ15. So at season when the air condition operated at full capacity, the hot water boiler or electric water heater could be closed. Furthermore in this paper the technical scheme and thermal analysis of air condition heat recovery are discussed.