热水供暖系统热量表的设置问题
The Problem of Installing Heat Meter in the Hot Water Heating System
【摘要】 采暖用热的多少是通过热量表来实现的 ,热量表设置位置不但影响到计量的初投资 ,还影响到计量的数据是否准确。本文对热量表的设置问题及热力入口装置进行了详细分析 ,建议多入口的建筑 ,应集中设置热量表 ;楼用热量表应设在供水管上 ,户用热量表设在供水管上或回水管上均可 ,但优先考虑设在供水管上。
【Abstract】 The heat measuring is achieved by heat meter.The location of the heat meter affects the initial investment of the heat measuring and the credibility of measure data.The article analyzes in detail the problem of installing the heat meter and the heating power installation on the entrances.It suggests that in the buildings with more entrances the heat meter should be installed centrally.It also suggests that the heat meter for the building should be installed on the supplying water tubes and for the consumers could be installed on the supplying tubes or the backwater tubes,but the former should be selected for the priority.