节点文献
尘土腐蚀对电接触表面的影响
Corrosion on Electric Contact Surfaces Due to Dust Contamination
【摘要】 对北京尘土中水溶性成分进行了分析测定 ,结果表明 :水溶性成分中含有K+ 、Na+ 、Ca2 + 、Mg2 + 、NH4 + 、SO4 2 - 、NO3- 、Cl- 、F- 、HCO3- 、NO2 - 等离子。对失效的连接器分析发现 :在电接触表面上有大量的污染物 ,腐蚀产物中含有K、Ca、S、Cl等尘土水溶性成分。文章探讨了尘土的腐蚀作用及尘土腐蚀对电接触可靠性的影响
【Abstract】 Analysis of the water soluble salts in airborne dust samples collected in Beijing has been carried out by various analytic methods, the results show that K +, Na +, Ca 2+ , Mg 2+ , NH 4 + , SO 4 2- , NO 3 -, Cl -, F -, HCO 3 - and NO 2 - exist in the water solution of dust. The failed connectors are inspected by scanning electron microscope and X ray energy spectroscope, serious contaminants are detected at the contact interfaces. The major elements of water soluble salts in dust such as K, Ca, S and Cl are found in part of the corrosion products. This paper discusses the corrosion effect of dust contamination on electric contact surfaces.
- 【文献出处】 机电元件 ,Electromechanical Components , 编辑部邮箱 ,2003年02期
- 【分类号】TM501.3
- 【被引频次】18
- 【下载频次】197