节点文献

常规变电站无人值班改造的一些经验

Some experiences in transformation from conventional subsatation to unattended substation

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 邹启群姜利军于颖

【Author】 ZOU Qi qun 1,JIANG Li jun 1,YU Ying 2 (1.Anyang Power Supply Bureau, Anyang 455000,China; 2.Anyang Iron & Steel Co.Ltd, Anyang 455000,China)

【机构】 安阳市电业局安阳钢铁集团公司 河南安阳455000河南安阳455000河南安阳455000

【摘要】 常规变电站实现无人值班 ,减少投资 ,减轻人员负担 ,减人增效 ,合理利用现有设备 ,是值得研究的问题。文章主要从技术、经济的角度讨论如何在 1 1 0kV常规变电站进行无人值班改造 ,并对常规的 2 2 0kV变电站实现无人值班提供一些有益的经验

【Abstract】 In period of integrated substation automation having developped rather ripely, the problems are worth of research that how to transform a conventional substation into an unattended one for the purpose of reducing investment and personal burden, increasing benifit on decreasing persons and utilizing the existing facilities reasonably. In this paper, how to carry out the transformation in 110kV conventional substation is discussed from the view of technique and economy so as to provide some experiences for the transformation of 220 kV conventional substation.