节点文献
透析液中氯化钾含量测定方法的改进
Improvement of the Determination Method of the Content of Potassium Chloride in Dialysate
【摘要】 目的:改进透析液中氯化钾含量测定方法提高回收率。方法:将原方法中四苯硼钠的浓度增加到0.02mol/l。结果:测得的回收率从原来的94.79%增加以100.15%。结论:改进后的方法准确、可靠。
【Abstract】 Object:To improve the determination method of the content of potassium of Sodium tetraphenylborate in the original method to 0.02mol/l.Result:Determined rcovery rate increased from 94.79% to 100.15% Conclusion:Improved method is accurate and reliable.
【关键词】 透析液;
氯化钾;
含量测定;
四苯硼钠;
【Key words】 dialysate; potassium chloride; content determination; Sodium tetraphenylborate;
【Key words】 dialysate; potassium chloride; content determination; Sodium tetraphenylborate;
- 【文献出处】 黑龙江医药 ,Heilongjiang Medical Journal , 编辑部邮箱 ,2003年06期
- 【分类号】R927
- 【下载频次】22