可变包含角单色器的双轴平行度误差分析和测试
Analysis and alignment of two unparalleled-axes of a variable included angle monochromator
【摘要】 估算了可变包含角单色器的两个旋转轴之间的不平行度对波长的调整精度和分辨率的影响,以及采用平行光管测量两个旋转轴的不平行度大小和调整的方法。
【Abstract】 The influence of two unparalleled axes of a variable included angle monochromator on wavelength tuning and resolution is discussed numerically in the text. And a method of measuring the unparallelism of two axes by using a paralleloscope and re-alignment of the axes is introduced.
【关键词】 变包含角单色器;
误差分析;
平行光管;
平行度测量;
【Key words】 Variable angle monochromator; Tolerance analysis; Paralleloscope; Parallelism measurement;
【Key words】 Variable angle monochromator; Tolerance analysis; Paralleloscope; Parallelism measurement;
- 【文献出处】 核技术 ,Nuclear Techniques , 编辑部邮箱 ,2003年06期
- 【分类号】TH741
- 【被引频次】2
- 【下载频次】113