奶粉中痕量汞的FI-AAS测定
Determination of Mercury in Powdered Milk by FI-AAS
【摘要】 探讨了流动注射 -原子吸收光谱法 (FI-AAS)测定痕量汞的分析条件 ,建立了奶粉中痕量汞的 FI-AAS测定方法。测定奶粉中汞的检出限为 2 .4 ng· g-1;线性范围 0— 80μg· L-1;相对标准偏差小于 5 % ;加标回收率为 95 %— 1 0 8%。该方法简便、快速
【Abstract】 Various testing conditions for determination of mercury by flow injection-atomic absorption spectrometry were discussed and a method for the determination of mercury in powdered milk was developed.The linear range for mercury is 0-80μg·L -1.The detection limit for mercury in powdered milk is 2.4ng·g -1.The relative standard deviation is less than 5% and the recovery is in the range of 95%-108%.This method is simple,rapid and can be applied to the determination of mercury in powdered milk samples with satisfactory results.