节点文献
电感耦合等离子体质谱测定地质样品中Pb同位素比值
Determination of Lead Isotope Ratios in Geological Samples by Inductively Coupled Plasma Mass Spectrometry
【Abstract】 A simple and precise method for direct determination of molar ratio of 206Pb/ 204Pb, 207Pb/ 204Pb and 208Pb/ 204Pb by ICP-MS was developed. The data acquirement parameters of MS for Quadrupole setting time(QST), Dwell time(DT), Integrated time and number of sweeps were investigated in detail. The relative standard deviation(RSD) of different Pb isotope ratios were less than 0.32%[n=5, ρ(Pb)=20 ng/mL]. The mass discrimination and dead time of detector was calibrated by using NIST981 solution. The mass bias factor(α) of 206Pb/ 204Pb, 207Pb/ 204Pb and 208Pb/ 204Pb were 0 002 5, 0 002 9 and 0 002 0, respectively. The dead time of detector was 7 ns. The proposed method has been applied to the analysis of geological standard reference materials containing AGV-1, BCR-2 and BHVO-2 .The relative error between this work and the recommend values or reported values was better than 0.73% and the relative standard deviation was better than 0.93%(n=5).
【Key words】 Inductively coupled plasma mass spectrometry(ICP-MS); Lead; Isotope ratio; Geological sample;
- 【文献出处】 高等学校化学学报 ,Chemical Research In Chinese Universities , 编辑部邮箱 ,2003年01期
- 【分类号】O657.63
- 【被引频次】7
- 【下载频次】354