电厂烟气脱硫副产物淋溶阴离子的测定
Determination of anions in eluate of flue gas desulfuration by-products
【摘要】 介绍了以离子色谱法测定电厂烟气脱硫副产品淋溶物阴离子的方法。测定淋溶释放的F-、Cl-及SO42 -的相对标准偏差分别为 13.5 %、5 .1%和 0 .6 7% ,回收率分别为 93.2 %~ 99.8%、93.8%~ 10 1.7%和95 .2 %~ 10 1.2 %。
【Abstract】 In power plants, the by products of flue gas desulfuration by LIFAC technology is solid materials. The anions in the eluate of these materials showered by rain have negative influence on the environment. The conventional methods for detecting these anions are colorimetry and gravimetry. This paper uses ion chromatography to determine the anions (F -, CI - and SO 4 2- ) in the eluate of the solid waste. The RSDs are 13.5%, 5.1% and 0.67%, and the recoveries are 93.2%~99.8%, 93.8%~101.7% and 95.2%~101.2% for F -, Cl - and SO 4 2- , respectively.
- 【文献出处】 分析仪器 ,Analytical Instrumentation , 编辑部邮箱 ,2003年04期
- 【分类号】O657.7
- 【下载频次】55