节点文献

光纤光导分光光度计

Optical Fiber Spectrophotometer

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 庄维新田果成叶国安周志宏程微微黄立峰刘素英唐延吉胡景忻赵永刚

【Author】 ZHUANG Weixin TIAN Guocheng YE Guoan ZHOU Zhihong CHENG Weiwei HUANG Lifeng LIU Suying TANG YanjiHU Jingxin ZHAO Yonggang (China Institute of Atomic Energy, Beijing)

【机构】 中国原子能科学研究院中国原子能科学研究院 北京北京北京

【摘要】 介绍了用“双臂光出电回”的方法把UV-365紫外/可见/近红外分光光度计改装成光纤光导分光光度计,光纤长5m。还介绍了用“单臂光出光回”的方法把λ19紫外/可见/近红外分光光度计改装成光纤光导分光光度计,光纤长10m。改装后的光纤光导分光光度计能和本机一样正常工作,所以,特别适用于放射性工作。

【Abstract】 A method called "Two Arm’s Photo out 8 Electricity Send-back" is introduced. UV-365 UV/VIS/NIR spectrophotometer has been reequiped by this way with 5 meters long optical fiber. Another method called "One Arm’s Photo out 8 Photo Send-back" is also introduced. r19 UV/VIS/NIR spectrophotometer has been reequiped by this way with 10 meters long optical fiber. Optical fiber spectrophotometer can work as its main set. So it is particularly applicable to radio activity work.