节点文献
用高效液相色谱法纯化制备rHuGM—CSF
Purification of Recombinant Human Granulocyte-macrophage Colony Stimulating Factor by HPLC
【摘要】 采用高效液相色谱(HPLC)的离子交换和凝胶过滤柱法,以 Tris·HCI作流动相, 280 nm波长检测,纯化重组人粒细胞-巨噬细胞集落刺激因子(rHuGM-CSF)。方法简便快捷并可得到99%高纯度的样品.终产物比活性达 1.0 × 107μ/mg蛋白,测定 N端 20个氨基酸序列与国内外文献报道的氨基酸序列完全一致.
【Abstract】 The rHuGM-CSF was purified by HPLC on ion-exchange column and Gel filtration column with Tris - HCl as mobile phase. The sample was purified to the purity of 99 % and to the specific activity of 1.0 ×107μ/mg. Meanwhile, the first 20 amino acids sequence of the N-terminal of the purified sample was identical to the ones that had been reported.
- 【文献出处】 云南大学学报(自然科学版) ,Journal of Yunnan University (Natural Sciences) , 编辑部邮箱 ,1998年S4期
- 【分类号】O657.7
- 【下载频次】49