节点文献

烷基化换热器的腐蚀失效分析和防护措施

Analysis of Heat Exchanger Failure of Alkylation Unit and Protection Measures

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【摘要】 通过对烷基化车间换热器腐蚀形貌、特征、产物、腐蚀介质、积垢、材料以及换热器流体特性的研究和分析,认为烷基化换热器的腐蚀失效主要由空泡腐蚀和湍流腐蚀引起,并提出了4项防腐蚀措施.经现场应用证明:改变设计或安排辅助管可以有效地减缓冷却管与管板结合部位的严重腐蚀.

【Abstract】 It was concluded from the studies and analysis of corrosion types, characteristics, corrosion products and corrosion media, fouling deposit and fluid properties of the heat exchangers in alkylation unit that the failure of the exchanger was mainly caused by bubbling corrosion and turbulent flow corrosion. Four corrosion protection measures were suggested. It was proven by site application that changing design or installing auxiliary pipes could effectively alleviate the severe corrosion at the joint of tubes and tube sheet.

【关键词】 heat exchangerfatigue analysisprotection
【Key words】 heat exchangerfatigue analysisprotection
  • 【文献出处】 石油化工腐蚀与防护 ,Petrochemical Corrosion and Protection , 编辑部邮箱 ,1998年04期
  • 【分类号】TQ205
  • 【被引频次】1
  • 【下载频次】110
节点文献中: 

本文链接的文献网络图示:

本文的引文网络