熏蒸空间磷化氢测定方法的研究
Studies on the Methods to Determine PH 3 in Fumigated Space
【摘要】 熏蒸空间PH3的测定用无动力采样和动力采样进行。两者间测定结果不存在显著差异。在实际工作中一些场合可用无动力采样代替动力采样。运用钼蓝比色法测定空气中PH3含量时,以720nm为测定波长较为适宜。对待测样品液稳定性分析的结果表明,未经显色处理及显色后盖上塞子的待测液较为稳定。24h内进行测定对最终结果不会产生影响。
【Abstract】 The studies on the methods to determine the amount of PH 3 in the fumigated space showed that there is no significant difference in final results between two methods of no power sampling and power sampling.The no power sampling can be used in practice instead of the power sampling.When determining the amount of PH 3 with the molybdenum blue spectrophotometry,it is proper to make 720 nm as wavelength for the determination.The analysis results on the steadiness of sample liquid showed that the untreated or unchanged blue sample liquid is steadier.There is no influence on the final results if determining within 24 hours.
- 【文献出处】 粮食与饲料工业 ,CEREAL & FEED INDUSTRY , 编辑部邮箱 ,1998年08期
- 【分类号】S482.6
- 【被引频次】5
- 【下载频次】44