抑制化学发光流动注射法测定水中苯酚
Determination of Phenic Acid in Phenolic Wastewater by Flow Injection with Inhibited Chemiluminescence Method.
【摘要】 本文根据苯酚对鲁米诺发光体系的抑制效应建立了水体中微量或痕量苯酚的测定方法。该方法线性范围为1×10-6~1×10-4mol/dm3,检出限为8×10-7mol/dm3,相对标准准偏差为12%
【Abstract】 This paper presents a new determinat method with flow injection inhibited chemiluminescence.This method for the determination of phenic acid in phenolic wastewater,the detection limit is 8×10 -7 mol/dm 3 and relative standard deviation 1 2%,the linear range is from 1×10 -6 to 1×10 -4 mol/dm 3.
- 【文献出处】 中国环境监测 ,ENVIRONMENTAL MONITORING IN CHINA , 编辑部邮箱 ,1998年06期
- 【分类号】X132
- 【被引频次】7
- 【下载频次】85