节点文献
絮凝-厌氧-好氧处理抗菌素废水的试验研究
Treatment of Antibiotic Wastewater by Flocculation A/O Process
【摘要】 血清瓶毒性实验表明,抗菌素废水对厌氧消化具有强烈的抑制作用,废水经过絮凝处理,可以降低废水的毒性.筛选到一种混凝剂(试剂B),可以去除废水COD50%.预处理后的废水经过厌氧污泥床(UASB)的处理,可以去除60%的COD,处理系统内形成了颗粒污泥.厌氧处理后的出水,再通过两级好氧处理,出水COD可降至300mg/L以下,达到生物制药废水行业排放标准.
【Abstract】 The toxicity experiment in serum bottle showed that antibiotic wastewater has serious inhibitory effect on anaerobic fermentation,pre treatment(flocculation)can reduce this inhibitory effect.A flocculant,regent B which can remove 50% COD of wastewater was obtained.After being pre treated,wastewater was treated by UASB reactor,60% COD was removed,and granular sludge was formed in reactor.Then the wastewater went through two grade aerobic treatment,the COD of effluent can be reduced to below 300mg/L,meeting the wastewater discharge standard of biological pharmacy.
【Key words】 antibiotic wastewater; toxicity; flocculant; UASB; aerobic treatment.;
- 【文献出处】 环境科学 ,CHINESE JOURNAL OF ENVIROMENTAL SCIENCE , 编辑部邮箱 ,1998年06期
- 【分类号】X780.3
- 【被引频次】71
- 【下载频次】284