节点文献

低压离子色谱法测定 Mg2+和 Ca2+ 离子

Analysis of Mg2+ and Ca2+ Lons in Water byLow Pressure Lon Chromatography

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 程作用饶仲群张劲松

【Author】 Cheng Zuoyong Rao Zhongqun Zhang Jingsong(Nuclear Power Institute of China,Chengdu,610005)

【机构】 中国核动力研究设计院

【摘要】 用低压离子色谱法测定水中的Mg2+和Ca2+离子,Mg2+离子在0~10μg/mL,Ca2+在0~12.5μg/mL浓度范围内,分别与其色谱峰具有良好的线性关系。Mg2+和Ca2+离子的检测限分别为0.173μg/mL和0.275μg/mL,其相对标准偏差分别为1.32%和3.64%,回收率分别为90.8%和101.3%。该方法快速、准确,适用于环境水样及放射性水样中Mg2+和Ca2+离子的分析。

【Abstract】 g2+ and Ca2+ ions in water are analyzed by low pressure ion chromatography.The results show that the concentration of Mg2+ and Ca2+ ions are linear with peaks of their chromatography in the range of 0~10μg/mL and 0~12.5μ/mL respectively and the minimum detectable concentration are 0.173μg/mL and 0.275μg/mL for Mg2+ and Ca2+ ions separately while relative standard deviations are 1.32% and 3.64% and the recovery rate are 90.8% and 101.3% respectively.The method is rapid and reliable.It can be applied to the measurement of Mg2+ and Ca2+ ions in water.

【关键词】 低压离子色谱法
【Key words】 owpressureionchromatographymethod Magnesium Calcium
  • 【文献出处】 核动力工程 ,NUCLEAR POWER ENGINEERING , 编辑部邮箱 ,1998年03期
  • 【分类号】TL271.4
  • 【下载频次】57
节点文献中: 

本文链接的文献网络图示:

本文的引文网络