氢化物-无色散原子荧光法同时测定钢铁中痕量硒和碲
DETERMINATION OF TRACE SELENIUM AND TELLURIUM IN STEEL BY HYDRIDE GENERATION NONDISPERSIVE ATOMIC FLUORESCENCE SPECTROMETRY
【摘要】 本文研究了氢化物-无色散原子荧光法同时测定钢铁中痕量硒和碲。采用离子交换法消除了阳离子干扰。在40%(V/V)盐酸介质测定硒和碲,方法检出限分别为0.27和0.33ng/mL,相对标准偏差分别为6.99和6.11%,回收率在96.7~102.0%之间。
【Abstract】 A method was developed for the determination of trace Se and Te in steel by ion exchange separation hydride generation nondispersive atomic fluorescence spectrometry.40%(V/V) chlorhydric acid was selected as the best medium for hydride reaction.The detection limits of Se and Te are 0 27 and 0 33 ng/mL,relative standard deviations are 6 99 and 6 11%,respectively.The recovery was in the range of 96 7—102 0%.The results are satisfactory.
【关键词】 氢化物;
原子荧光法;
硒;
碲;
离子交换;
【Key words】 Hydride; Atomic fluorescence spectrometry; Selenium; Tellurium; Ion exchange;
【Key words】 Hydride; Atomic fluorescence spectrometry; Selenium; Tellurium; Ion exchange;
【基金】 冶金部科技司资助
- 【文献出处】 光谱学与光谱分析 ,SPECTROSCOPY AND SPECTRAL ANALYSIS , 编辑部邮箱 ,1998年06期
- 【分类号】O657.31
- 【被引频次】29
- 【下载频次】83