节点文献
供水车间循环水泵轴断裂失效分析
CORROSION FATIGUE FAILURE ANALYSIS OF THE PUMP SHAFT
【摘要】 通过对循环水泵轴断裂失效的宏观和微观分析,得出该循环水泵轴的失效属于腐蚀疲劳破坏,是弯曲循环载荷和循环水中的Cl~-离子共同作用的结果,并对今后防止这类失效提出了建议.
【Abstract】 The failure reason of a pump shaft was analyzed by means of optical microscope and scanning electron microscope. The results showed that the failure was caused not only by fatigue but also by chlorion stress corrosion. Some proposals were given in order to prevent from failure of the water-pump shaft.
- 【文献出处】 腐蚀与防护 ,Corrosion & Protection , 编辑部邮箱 ,1998年06期
- 【分类号】TG179
- 【下载频次】63