绍兴县医疗单位消毒工作调查
SURVEY OF DISINFECTION WORK IN MEDICAL INSTITUTIONS OF SHAOXING COUNTY
【摘要】 经检测,使用中1.0%过氧乙酸、0.5%聚维酮碘、0.5%~1.0%戊二醛、75.0%乙醇与0.1%新洁尔灭溶液微生物污染超标率分别为0.0%、0.0%、1.1%、35.2%与28.8%。压力蒸汽灭菌的注射器存放7 天内与多于7天的无菌合格率分别为92.3%与81.2%,煮沸的注射器则分别为63.8%与43.8%。有卫生许可证紫外线灯管的辐照度值合格率(91.2%)高于无证紫外线灯管者(64.9%)。
【Abstract】 Examination found that the rates of microbial contamination exceeding permissible limit(≤250 cfu/ml) in 1.0% peracetic acid,0.5% PVP-I,0.5%~1.0% glutaraldehyde,75.0% ethyl alcohol and 0.1% bromogeramine solutions in use were 0.0%,0.0%,1.1%,35.2% and 28.8% respectively.The rates of eligible sterilization in autoclaved syringes were 92.3% and 81.2% after storing for 7 days and longer than 7 days respectively,while those of boiled syringes were 63.8 % and 43.8% respectively.The rate of eligible radiation value in ultraviolet lamps with sanitary licence(91.2%)was higher than that in ultraviolet lamps without li- cence(64.9%).
- 【文献出处】 中国消毒学杂志 ,Chinese Journal of Disinfection , 编辑部邮箱 ,1997年01期